TECHNICAL GUIDE

Cat6, Cat6A, Cat7 or fiber? Choosing network cabling

Cabling is installed once and stays in your walls and ceilings for 15 years or more. Here is what each option really gives you, in plain language, so you can choose for the years ahead, not just for today.

In this guide
  1. Find your cable
  2. Choose by need
  3. Side by side
  4. Cat7 and Cat7A
  5. Shielding
  6. LSZH jacket
  7. Choose for the future
  8. Installation quality
  9. PoE and Wi-Fi
  10. Common mistakes

Related guides

  • 15+ yearsHow long cabling usually stays in a building
  • 100 mLongest copper link: 90 m of fixed cable plus cords
  • 90 WPower a switch can send over PoE (IEEE 802.3bt)
  • Up to 25 yearsSystem warranty many manufacturers offer with a certified installer

Choose by need, not by office size

A small office with high-performance equipment can need more than a large office with basic needs. Start from what the network has to carry.

Your situation Recommended
Only 1 Gbps needed, short-term siteCat6
New building, modern Wi-Fi (Wi-Fi 6E or Wi-Fi 7), or 10 GbpsCat6A
Heavy electrical interference, or the specifications require itCat7 or Cat7A (shielded)
Between floors or buildings, or longer than 100 mFiber: OM4 inside a building, OS2 between distant buildings
Data center, switch to serverFiber and Cat6A, or Cat8 for links up to 30 m

The options side by side

Cable Bandwidth Speed and distance Good to know
Cat6250 MHz1 Gbps up to 100 m. 10 Gbps only on short runs (roughly 37 to 55 m, depending on conditions).Thinner and easier to install.
Cat6A500 MHz10 Gbps up to the full 100 m.Thicker: needs larger pathways and cabinets. Handles PoE heat better.
Cat7 / Cat7A600 / 1000 MHzWith standard RJ45 connectors: 10 Gbps up to 100 m, like Cat6A.Fully shielded. Needs correct grounding.
Cat82000 MHz25 or 40 Gbps up to 30 m.For data centers.
Fiber OM4 (multimode)-10 Gbps up to about 400 m.Inside buildings and campuses.
Fiber OS2 (singlemode)-Kilometers.Between buildings, and ready for future speeds.

Cat7 and Cat7A in plain words

  • On paper they are faster than Cat6A. They are defined in the international ISO standard, but the American TIA standard does not include them.
  • To reach their full speed they need special connectors called GG45 or TERA, instead of the standard RJ45 plug found on every device. With normal RJ45 they perform about the same as Cat6A: 10 Gbps up to 100 m.
  • They are fully shielded, so they help where electrical interference is heavy, such as factories and plant rooms, as long as they are grounded correctly at both ends.
  • NC Solution supplies and installs Cat7 and Cat7A cabling, including indoor/outdoor cables with rodent protection, and duplex cables (two cables in one jacket) that save installation time.

Shielding in one minute

Shielding is a metal layer around the wires inside the cable. It protects the signal from electrical interference (EMI) coming from machines or nearby power cables. The name tells you where the shielding is: the letter before the slash is the layer around the whole cable, the letters after it describe each pair (TP means twisted pair).

Cross-sections of four cable types, from left: U/UTP, F/UTP, F/FTP and S/FTP
From left: U/UTP, F/UTP, F/FTP, S/FTP. Illustration.
U/UTP
No shielding. Most Cat6 office cabling is this type.
F/UTP
A foil around the whole cable.
F/FTP
A foil around each pair and around the whole cable.
S/FTP
A foil around each pair and a braided screen around the whole cable. The highest protection.

Important: shielded cable without proper grounding can perform worse than unshielded cable.

LSZH jacket: a safety choice

LSZH (Low Smoke Zero Halogen) jackets give off less smoke and no toxic halogen gases in a fire. We recommend them in enclosed buildings, whatever the cable category. Ask for it to be written in the quote.

Why choose for the future

  • Cabling lasts 15 years or more, while network equipment is usually replaced every 5 to 7 years.
  • The cable is a small part of the project cost, but replacing it later is expensive: ceilings are opened and work stops.

Installation quality matters as much as the cable

  • A link performs only as well as its weakest part: the cable, jacks, patch panels and patch cords.
  • Use components from one manufacturer's system rather than mixing parts.
  • Every point should be tested with a certification tester, and you should receive the test report. It gives the details of every cable, and if there is a fault it shows where.
  • Many manufacturers offer a system warranty of up to 25 years when a certified installer does the work and submits the test results.

PoE and Wi-Fi

  • PoE to the IEEE 802.3bt standard can deliver up to 90 W from the switch. Large bundles of powered cables heat up, and Cat6A handles that heat better.
  • Wi-Fi does not remove cables: every access point needs one. Wireless manufacturers recommend Cat6A for Wi-Fi 6E and Wi-Fi 7 access points, which use 2.5 to 10 Gbps.
  • Tip: if the budget allows, two cables per access point prepare you for the future.

Common mistakes

  • CCA cable (copper-clad aluminium). It does not meet the standards and is risky with PoE. Make sure the cable is solid copper.
  • Running data cables next to power cables without enough separation.
  • Permanent cable runs longer than 90 m (100 m for the whole link).
  • No labels on the cables and no as-built drawings at handover.