In this guide
- Find your cable
- Choose by need
- Side by side
- Cat7 and Cat7A
- Shielding
- LSZH jacket
- Choose for the future
- Installation quality
- PoE and Wi-Fi
- Common mistakes
Related guides
- 15+ yearsHow long cabling usually stays in a building
- 100 mLongest copper link: 90 m of fixed cable plus cords
- 90 WPower a switch can send over PoE (IEEE 802.3bt)
- Up to 25 yearsSystem warranty many manufacturers offer with a certified installer
Which cable fits you? Answer a few questions
Pick an answer for each question and you will see our suggestion straight away.
Cat6
Enough for 1 Gbps on a short-term site. If the site may be used for longer, choose Cat6A.
Estimate your cabling →Cat6A
10 Gbps up to 100 m, ready for modern Wi-Fi and the heat of PoE, for the many years the cabling will stay in place.
Estimate your cabling →Cat7 or Cat7A (shielded)
Full shielding protects against heavy interference. It must be grounded correctly at both ends.
Estimate your cabling →Fiber OM4 (multimode)
Inside a building or campus, OM4 carries 10 Gbps up to about 400 m.
Request a quote →Fiber OS2 (singlemode)
Reaches kilometers between buildings and is ready for future speeds.
Request a quote →Fiber and Cat6A, or Cat8
For switch-to-server links: fiber and Cat6A, or Cat8 for short links up to 30 m.
Estimate your server room →A starting point based on this guide, not a design. We confirm the right choice on the free site visit.
Choose by need, not by office size
A small office with high-performance equipment can need more than a large office with basic needs. Start from what the network has to carry.
| Your situation | Recommended |
|---|---|
| Only 1 Gbps needed, short-term site | Cat6 |
| New building, modern Wi-Fi (Wi-Fi 6E or Wi-Fi 7), or 10 Gbps | Cat6A |
| Heavy electrical interference, or the specifications require it | Cat7 or Cat7A (shielded) |
| Between floors or buildings, or longer than 100 m | Fiber: OM4 inside a building, OS2 between distant buildings |
| Data center, switch to server | Fiber and Cat6A, or Cat8 for links up to 30 m |
The options side by side
| Cable | Bandwidth | Speed and distance | Good to know |
|---|---|---|---|
| Cat6 | 250 MHz | 1 Gbps up to 100 m. 10 Gbps only on short runs (roughly 37 to 55 m, depending on conditions). | Thinner and easier to install. |
| Cat6A | 500 MHz | 10 Gbps up to the full 100 m. | Thicker: needs larger pathways and cabinets. Handles PoE heat better. |
| Cat7 / Cat7A | 600 / 1000 MHz | With standard RJ45 connectors: 10 Gbps up to 100 m, like Cat6A. | Fully shielded. Needs correct grounding. |
| Cat8 | 2000 MHz | 25 or 40 Gbps up to 30 m. | For data centers. |
| Fiber OM4 (multimode) | - | 10 Gbps up to about 400 m. | Inside buildings and campuses. |
| Fiber OS2 (singlemode) | - | Kilometers. | Between buildings, and ready for future speeds. |
Cat7 and Cat7A in plain words
- On paper they are faster than Cat6A. They are defined in the international ISO standard, but the American TIA standard does not include them.
- To reach their full speed they need special connectors called GG45 or TERA, instead of the standard RJ45 plug found on every device. With normal RJ45 they perform about the same as Cat6A: 10 Gbps up to 100 m.
- They are fully shielded, so they help where electrical interference is heavy, such as factories and plant rooms, as long as they are grounded correctly at both ends.
- NC Solution supplies and installs Cat7 and Cat7A cabling, including indoor/outdoor cables with rodent protection, and duplex cables (two cables in one jacket) that save installation time.
Shielding in one minute
Shielding is a metal layer around the wires inside the cable. It protects the signal from electrical interference (EMI) coming from machines or nearby power cables. The name tells you where the shielding is: the letter before the slash is the layer around the whole cable, the letters after it describe each pair (TP means twisted pair).
- U/UTP
- No shielding. Most Cat6 office cabling is this type.
- F/UTP
- A foil around the whole cable.
- F/FTP
- A foil around each pair and around the whole cable.
- S/FTP
- A foil around each pair and a braided screen around the whole cable. The highest protection.
Important: shielded cable without proper grounding can perform worse than unshielded cable.
LSZH jacket: a safety choice
LSZH (Low Smoke Zero Halogen) jackets give off less smoke and no toxic halogen gases in a fire. We recommend them in enclosed buildings, whatever the cable category. Ask for it to be written in the quote.
Why choose for the future
- Cabling lasts 15 years or more, while network equipment is usually replaced every 5 to 7 years.
- The cable is a small part of the project cost, but replacing it later is expensive: ceilings are opened and work stops.
Installation quality matters as much as the cable
- A link performs only as well as its weakest part: the cable, jacks, patch panels and patch cords.
- Use components from one manufacturer's system rather than mixing parts.
- Every point should be tested with a certification tester, and you should receive the test report. It gives the details of every cable, and if there is a fault it shows where.
- Many manufacturers offer a system warranty of up to 25 years when a certified installer does the work and submits the test results.
PoE and Wi-Fi
- PoE to the IEEE 802.3bt standard can deliver up to 90 W from the switch. Large bundles of powered cables heat up, and Cat6A handles that heat better.
- Wi-Fi does not remove cables: every access point needs one. Wireless manufacturers recommend Cat6A for Wi-Fi 6E and Wi-Fi 7 access points, which use 2.5 to 10 Gbps.
- Tip: if the budget allows, two cables per access point prepare you for the future.
Common mistakes
- CCA cable (copper-clad aluminium). It does not meet the standards and is risky with PoE. Make sure the cable is solid copper.
- Running data cables next to power cables without enough separation.
- Permanent cable runs longer than 90 m (100 m for the whole link).
- No labels on the cables and no as-built drawings at handover.